Specifications
Status |
Mass Production (Preferred) |
Inductance |
33 uH ± 5 % |
Case Size (EIA/JIS) |
0806/2016 |
Rated Current (max) |
0.125 A |
DC Resistance (max) |
4.68 Ω |
DC Resistance (typ) |
3.6 Ω |
Q (min) |
25 |
Self Resonant Frequency (min) |
15 MHz |
Operating Temp. Range |
-40 to +105 ℃ (Including-self-generated heat) |
Temperature characteristic (Inductance change) |
± 5 % |
Dimension L |
2.0 ±0.2 mm |
Dimension W |
1.6 ±0.2 mm |
Dimension T |
1.6 ±0.2 mm |
Dimension e |
0.5 ±0.2 mm |
Measuring Frequency |
2.52 MHz |
RoHS Compliance (10 subst.) |
Yes |
REACH Compliance (240 subst.) |
Yes |
IEC62474 (Ver. D28.00) Compliance |
Yes |
Halogen Free |
Yes |
Soldering |
Reflow |
Standard Quantity |
Taping Embossed 2000pcs |
|
Appearance
|
Features
Wound chip inductors for signal line propose Down sizing with High Q and narrow tolerance
|
Main Applications
For Medical Devices classified as GHTF Classes A to B (Japan Classes Ⅰ to Ⅱ)
Suitable for the analog signal line
|
|
Document
|
Simulation data
|
Links
|
RoHS and REACH Certificate of Compliance
|
Characteristic value graphs
|
Rated Current : The maximum DC value having inductance decrease within 10 % and temperature increase within 20 degC by the application of DC bias.
Please contact our sales staff when ordering or inquiring the details about products on our website.
|