INDUCTORS  [Wire-wound Ferrite Power Inductors LSXB/LSXN/LSXP series for General Electronic Equipment]

Specifications

Status Mass Production (Preferred)
Inductance 1.5 uH ± 30 %
Case Size (mm) 2.0x2.0
Rated Current (max) 1.5 A
Saturation Current (max) 1.65 A (⊿L=30%)
Saturation Current (typ) 1.8 A (⊿L=30%)
Temperature Rise Current (max) 1.5 A (⊿T=40℃)
Temperature Rise Current (typ) 1.65 A (⊿T=40℃)
DC Resistance (max) 108 mΩ
DC Resistance (typ) 90 mΩ
Operating Temp. Range -25 to +120 ℃
(Including-self-generated heat)
Temperature characteristic
(Inductance change)
± 20 %
Dimension L 2.0 ±0.1 mm
Dimension W 2.0 ±0.1 mm
Dimension H Max 1.2 mm
Dimension e 0.5 ±0.2 mm
Dimension f 1.25 ±0.2 mm
Measuring Frequency 100 kHz
RoHS Compliance (10 subst.) Yes
REACH Compliance (247 subst.) Yes
Halogen Free Yes
Soldering Reflow
Standard Quantity Taping Embossed 2500pcs

Appearance

To Higher Specification

Smaller
Lo-Rdc Lower
Hi-Curr.

Features

Small and Low profile inductor

It corresponds to High current

Durable structure against dropping impact

Main Applications

For small DC/DC converter
(cellular Phone, HDD, DVC, DSC, PDA, LCD display etc.)

Document

 

Simulation data

Links

 

RoHS and REACH Certificate of Compliance

Characteristic value graphs

JavaScript chart by amCharts 3.21.3LSXND2020MKT1R5N0GImpedance0.010.11101001,00010,000Frequency[MHz]0.11101001,00010,000Impedance[ohm]
JavaScript chart by amCharts 3.21.3[Z]
JavaScript chart by amCharts 3.21.3LSXND2020MKT1R5N0GInductance0.010.11101001,000Frequency[MHz]0.010.1110100Inductance[uH]
JavaScript chart by amCharts 3.21.3[L]
JavaScript chart by amCharts 3.21.3LSXND2020MKT1R5N0GDC Bias(L)00.511.522.5DC Bias[A]00.20.40.60.811.21.41.6Inductance[uH]
JavaScript chart by amCharts 3.21.3[DCB(L)]
JavaScript chart by amCharts 3.21.3LSXND2020MKT1R5N0GTemperature Rise00.511.52DC Bias[A]010203040506070Self Temperature Rise[degC]
JavaScript chart by amCharts 3.21.3[Temp.Rise.]
The saturation current value is the DC current value having inductance decrease down to 30%. (at 20℃)
The temperature rise current value is the DC current value having temperature increase up to 40℃. (at 20℃)
Please contact our sales staff when ordering or inquiring the details about products on our website.
Information