INDUCTORS  [Wire-wound Ferrite Inductors LLQB/LLQC/LLQE series for Medical Devices classified as GHTF Classes A or B (Japan Classes I or II)]

产品规格

Status Mass Production (Preferred)
Inductance 15 uH ± 10 %
Case Size (EIA/JIS) 1207/3218
Rated Current (max) 0.3 A
DC Resistance (max) 0.416 Ω
DC Resistance (typ) 0.32 Ω
Self Resonant Frequency (min) 25 MHz
Operating Temp. Range -40 to +105 ℃
(Including-self-generated heat)
Temperature characteristic
(Inductance change)
± 25 %
Dimension L 3.2 ±0.2 mm
Dimension W 1.8 ±0.2 mm
Dimension T 1.8 ±0.2 mm
Dimension e 0.6 ±0.2 mm
Measuring Frequency 2.52 MHz
RoHS Compliance (10 subst.) Yes
REACH Compliance (247 subst.) Yes
Halogen Free Yes
Soldering Reflow
Standard Quantity Taping Embossed 2000pcs

外观

高性能建议

Smaller
Hi-Temp. Lower
Hi-Curr.

特征

Wound Chip Inductors having wide line-up, which are suitable
for any circuit designs

主要用途

For Medical Devices classified as GHTF Classes A to B (Japan Classes Ⅰ to Ⅱ)

They are suitable for an anti-noise measure on the power supply circuit

产品資料

 

模拟数据

链接

 

关于产品的环保证明书

特徵值圖

JavaScript chart by amCharts 3.21.3LLQBA321818T150KImpedance0.010.11101001,000Frequency[MHz]1101001,00010,000100,000Impedance[ohm]
JavaScript chart by amCharts 3.21.3[Z]
JavaScript chart by amCharts 3.21.3LLQBA321818T150KInductance0.010.1110100Frequency[MHz]1101001,000Inductance[uH]
JavaScript chart by amCharts 3.21.3[L]
JavaScript chart by amCharts 3.21.3LLQBA321818T150KDC Bias(L)00.10.20.30.40.5DC Bias[A]024681012141618Inductance[uH]
JavaScript chart by amCharts 3.21.3[DCB(L)]
Rated Current : The maximum DC value having inductance decrease within 10 % and temperature increase within 20 degC by the application of DC bias.