INDUCTORS  [Wire-wound Ferrite Power Inductors LLQN/LLQPA series for Medical Devices classified as GHTF Classes A or B (Japan Classes I or II)]

Specifications

Status Mass Production (Preferred)
Inductance 15 uH ± 10 %
Case Size (EIA/JIS) 1210/3225
Rated Current (max) 0.73 A
Saturation Current (max) 0.73 A (⊿L=30%)
Temperature Rise Current (max) 0.85 A (⊿T=40℃)
DC Resistance (max) 0.2535 Ω
DC Resistance (typ) 0.195 Ω
Self Resonant Frequency (min) 20 MHz
Operating Temp. Range -40 to +105 ℃
(Including-self-generated heat)
Temperature characteristic
(Inductance change)
± 20 %
Dimension L 3.2 ±0.2 mm
Dimension W 2.5 ±0.2 mm
Dimension T 2.5 ±0.2 mm
Dimension e 0.6 ±0.3 mm
Measuring Frequency 0.1 MHz
RoHS Compliance (10 subst.) Yes
REACH Compliance (240 subst.) Yes
IEC62474 (Ver. D28.00) Compliance Yes
Halogen Free Yes
Soldering Reflow
Standard Quantity Taping Embossed 1000pcs

Appearance

To Higher Specification

Smaller
Lo-Rdc Lower
Hi-Curr.

Features

Wound Chip Inductors having wide line-up, which are suitable
for any circuit designs

Main Applications

For Medical Devices classified as GHTF Classes A to B (Japan Classes Ⅰ to Ⅱ)

They are suitable for an anti-noise measure on the power supply circuit

Document

 

Simulation data

Links

 

RoHS and REACH Certificate of Compliance

Characteristic value graphs

The saturation current value is the DC current value having inductance decrease down to 30%. (at 20℃)
The temperature rise current value is the DC current value having temperature increase up to 40℃. (at 20℃)
Please contact our sales staff when ordering or inquiring the details about products on our website.
{{title}}