Specifications

Status Mass Production (Preferred)
Inductance 0.24 uH ± 20 %
Case Size (EIA/JIS) 0603/1608
Rated Current (max) 2.1 A
Saturation Current (max) 2.3 A (⊿L=30%)
Saturation Current (typ) 2.7 A (⊿L=30%)
Temperature Rise Current (max) 2.1 A (⊿T=40℃)
Temperature Rise Current (typ) 2.4 A (⊿T=40℃)
DC Resistance (max) 50 mΩ
DC Resistance (typ) 40 mΩ
Operating Temp. Range -40 to +125 ℃
(Including-self-generated heat)
Dimension L 1.6 ±0.2 mm
Dimension W 0.8 ±0.2 mm
Dimension T Max 0.6 mm
Dimension e 0.3 ±0.2 mm
Measuring Frequency 1 MHz
RoHS Compliance (10 subst.) Yes
REACH Compliance (247 subst.) Yes
Halogen Free Yes
Soldering Reflow
Standard Quantity Taping Paper 4000pcs

Appearance

To Higher Specification

Smaller
Lo-Rdc Lower
Hi-Curr.

Features

Use of metallic magnetic materials which has excellent DC bias characteristic

Main Applications

For Medical Devices classified as GHTF Classes A to B (Japan Classes Ⅰ to Ⅱ)

For small DC/DC converter

Document

 

Simulation data


Links

 

RoHS and REACH Certificate of Compliance

Characteristic value graphs

JavaScript chart by amCharts 3.21.3LLCNA1608FKTR24MAImpedance0.11101001,000Frequency[MHz]0.11101001,00010,000Impedance[ohm]
JavaScript chart by amCharts 3.21.3[Z]
JavaScript chart by amCharts 3.21.3LLCNA1608FKTR24MAInductance0.11101001,000Frequency[MHz]0.0010.010.1110Inductance[uH]
JavaScript chart by amCharts 3.21.3[L]
JavaScript chart by amCharts 3.21.3LLCNA1608FKTR24MADC Bias(L)00.511.522.53DC Bias[A]00.050.10.150.20.25Inductance[uH]
JavaScript chart by amCharts 3.21.3[DCB(L)]
The saturation current value is the DC current value having inductance decrease down to 30%. (at 20℃)
The temperature rise current value is the DC current value having temperature increase up to 40℃. (at 20℃)
Please contact our sales staff when ordering or inquiring the details about products on our website.