INDUCTORS  [Multilayer Metal Power Inductors MCOIL™ LLCN series for Medical Devices classified as GHTF Classes A or B (Japan Classes I or II)]

Specifications

Status Mass Production (Preferred)
Inductance 0.47 uH ± 20 %
Case Size (EIA/JIS) 0805/2012
Rated Current (max) 3.1 A
Saturation Current (max) 4.5 A (⊿L=30%)
Saturation Current (typ) 4.9 A (⊿L=30%)
Temperature Rise Current (max) 3.1 A (⊿T=40℃)
Temperature Rise Current (typ) 3.5 A (⊿T=40℃)
DC Resistance (max) 39 mΩ
DC Resistance (typ) 32 mΩ
Operating Temp. Range -40 to +125 ℃
(Including-self-generated heat)
Dimension L 2.0 ±0.2 mm
Dimension W 1.25 ±0.2 mm
Dimension T Max 1.0 mm
Dimension e 0.5 ±0.3 mm
Measuring Frequency 1 MHz
RoHS Compliance (10 subst.) Yes
REACH Compliance (247 subst.) Yes
Halogen Free Yes
Soldering Reflow
Standard Quantity Taping Embossed 3000pcs

Appearance

To Higher Specification

Smaller
Lo-Rdc Lower
Hi-Curr.

Features

Use of metallic magnetic materials which has excellent DC bias characteristic

Main Applications

For Medical Devices classified as GHTF Classes A to B (Japan Classes Ⅰ to Ⅱ)

For small DC/DC converter

Document

 

Simulation data


Links

 

RoHS and REACH Certificate of Compliance

Characteristic value graphs

JavaScript chart by amCharts 3.21.3LLCNA2012KKTR47MAQ101001,00010,000Frequency[MHz]0510152025303540Q
JavaScript chart by amCharts 3.21.3HK100515NJ-T [Q]
JavaScript chart by amCharts 3.21.3LLCNA2012KKTR47MAQ101001,00010,000Frequency[MHz]0510152025303540Q
JavaScript chart by amCharts 3.21.3HK100515NJ-T [Q]
JavaScript chart by amCharts 3.21.3LLCNA2012KKTR47MAQ101001,00010,000Frequency[MHz]0510152025303540Q
JavaScript chart by amCharts 3.21.3HK100515NJ-T [Q]
The saturation current value is the DC current value having inductance decrease down to 30%. (at 20℃)
The temperature rise current value is the DC current value having temperature increase up to 40℃. (at 20℃)
Please contact our sales staff when ordering or inquiring the details about products on our website.
Information