INDUCTORS  [Wire-wound Metal Power Inductors MCOIL™ LLDN series for Medical Devices classified as GHTF Classes A or B (Japan Classes I or II)]

Specifications

Status Mass Production (Preferred)
Inductance 0.56 uH ± 30 %
Case Size (mm) 4.0x4.0
Rated Current (max) 6.5 A
Saturation Current (max) 9 A (⊿L=30%)
Saturation Current (typ) 13 A (⊿L=30%)
Temperature Rise Current (max) 6.5 A (⊿T=40℃)
Temperature Rise Current (typ) 7.5 A (⊿T=40℃)
DC Resistance (max) 16 mΩ
DC Resistance (typ) 14 mΩ
Operating Temp. Range -40 to +125 ℃
(Including-self-generated heat)
Temperature characteristic
(Inductance change)
± 10 %
Dimension L 4.0 ±0.2 mm
Dimension W 4.0 ±0.2 mm
Dimension H Max 2.0 mm
Dimension e 1.1 ±0.2 mm
Dimension f 2.5 ±0.2 mm
Measuring Frequency 1 MHz
RoHS Compliance (10 subst.) Yes
REACH Compliance (247 subst.) Yes
Halogen Free Yes
Soldering Reflow
Standard Quantity Taping Embossed 700pcs

Appearance

To Higher Specification

Smaller
Lo-Rdc Lower
Hi-Curr.

Features

Use of metallic magnetic materials which has excellent DC bias characteristic

Main Applications

For Medical Devices classified as GHTF Classes A to B (Japan Classes Ⅰ to Ⅱ)

For DC/DC converter

Document

 

Simulation data

Links

 

RoHS and REACH Certificate of Compliance

Characteristic value graphs

JavaScript chart by amCharts 3.21.3LLDND4040WKTR56NMImpedance0.010.11101001,000Frequency[MHz]0.010.11101001,00010,000Impedance[ohm]
JavaScript chart by amCharts 3.21.3[Z]
JavaScript chart by amCharts 3.21.3LLDND4040WKTR56NMInductance0.010.11101001,000Frequency[MHz]0.0010.010.1110Inductance[uH]
JavaScript chart by amCharts 3.21.3[L]
JavaScript chart by amCharts 3.21.3LLDND4040WKTR56NMDC Bias(L)024681012141618DC Bias[A]00.10.20.30.40.50.6Inductance[uH]
JavaScript chart by amCharts 3.21.3[DCB(L)]
JavaScript chart by amCharts 3.21.3LLDND4040WKTR56NMTemperature Rise012345678910DC Bias[A]010203040506070Self Temperature Rise[degC]
JavaScript chart by amCharts 3.21.3[Temp.Rise.]
The saturation current value is the DC current value having inductance decrease down to 30%. (at 20℃)
The temperature rise current value is the DC current value having temperature increase up to 40℃. (at 20℃)
Please contact our sales staff when ordering or inquiring the details about products on our website.
Information