INDUCTORS  [Wire-wound Ferrite Inductors LLQB/LLQC/LLQE series for Medical Devices classified as GHTF Classes A or B (Japan Classes I or II)]

Specifications

Status Mass Production (Preferred)
Inductance 680 uH ± 20 %
Case Size (EIA/JIS) 1207/3218
Rated Current (max) 45 mA
DC Resistance (max) 22.1 Ω
DC Resistance (typ) 17 Ω
Self Resonant Frequency (min) 3 MHz
Operating Temp. Range -40 to +105 ℃
(Including-self-generated heat)
Temperature characteristic
(Inductance change)
± 25 %
Dimension L 3.2 ±0.2 mm
Dimension W 1.8 ±0.2 mm
Dimension T 1.8 ±0.2 mm
Dimension e 0.6 ±0.2 mm
Measuring Frequency 0.796 MHz
RoHS Compliance (10 subst.) Yes
REACH Compliance (247 subst.) Yes
Halogen Free Yes
Soldering Reflow
Standard Quantity Taping Embossed 2000pcs

Appearance

To Higher Specification

Smaller
Hi-Temp. Lower
Hi-Curr.

Features

Wound Chip Inductors having wide line-up, which are suitable
for any circuit designs

Main Applications

For Medical Devices classified as GHTF Classes A to B (Japan Classes Ⅰ to Ⅱ)

They are suitable for an anti-noise measure on the power supply circuit

Document

 

Simulation data

Links

 

RoHS and REACH Certificate of Compliance

Characteristic value graphs

Rated Current : The maximum DC value having inductance decrease within 10 % and temperature increase within 20 degC by the application of DC bias.