INDUCTORS  [Wire-wound Ferrite Power Inductors LLQN/LLQPA series for Medical Devices classified as GHTF Classes A or B (Japan Classes I or II)]

Specifications

Status Mass Production (Preferred)
Inductance 330 uH ± 10 %
Case Size (EIA/JIS) 1007/2518
Rated Current (max) 40 mA
Saturation Current (max) 40 mA (⊿L=30%)
Temperature Rise Current (max) 140 mA (⊿T=40℃)
DC Resistance (max) 9.1 Ω
DC Resistance (typ) 7 Ω
Self Resonant Frequency (min) 4.5 MHz
Operating Temp. Range -40 to +105 ℃
(Including-self-generated heat)
Temperature characteristic
(Inductance change)
± 20 %
Dimension L 2.5 ±0.2 mm
Dimension W 1.8 ±0.2 mm
Dimension T 1.8 ±0.2 mm
Dimension e 0.5 ±0.2 mm
Measuring Frequency 0.796 MHz
RoHS Compliance (10 subst.) Yes
REACH Compliance (247 subst.) Yes
Halogen Free Yes
Soldering Reflow
Standard Quantity Taping Embossed 2000pcs

Appearance

To Higher Specification

Smaller
Lo-Rdc Lower
Hi-Curr.

Features

Wound Chip Inductors having wide line-up, which are suitable
for any circuit designs

Main Applications

For Medical Devices classified as GHTF Classes A to B (Japan Classes Ⅰ to Ⅱ)

They are suitable for an anti-noise measure on the power supply circuit

Document

 

Simulation data

Links

 

RoHS and REACH Certificate of Compliance

Characteristic value graphs

JavaScript chart by amCharts 3.21.3LLQNA251818T331KImpedance0.010.11101001,000Frequency[MHz]101001,00010,000100,0001,000,000Impedance[ohm]
JavaScript chart by amCharts 3.21.3[Z]
JavaScript chart by amCharts 3.21.3LLQNA251818T331KInductance0.010.1110100Frequency[MHz]101001,00010,000100,000Inductance[uH]
JavaScript chart by amCharts 3.21.3[L]
JavaScript chart by amCharts 3.21.3LLQNA251818T331KDC Bias(L)00.020.040.060.08DC Bias[A]050100150200250300350400Inductance[uH]
JavaScript chart by amCharts 3.21.3[DCB(L)]
The saturation current value is the DC current value having inductance decrease down to 30%. (at 20℃)
The temperature rise current value is the DC current value having temperature increase up to 40℃. (at 20℃)
Please contact our sales staff when ordering or inquiring the details about products on our website.
Information
Please be sure to read PRECAUTIONS AND DISCLAIMERS before you use TY-COMPAS.