INDUCTORS  [Wire-wound Ferrite Power Inductors LLQN/LLQPA series for Medical Devices classified as GHTF Classes A or B (Japan Classes I or II)]

Specifications

Status Mass Production (Preferred)
Inductance 1.0 uH ± 20 %
Case Size (EIA/JIS) 0603/1608
Rated Current (max) 0.29 A
Saturation Current (max) 0.29 A (⊿L=30%)
Temperature Rise Current (max) 0.77 A (⊿T=40℃)
DC Resistance (max) 117 mΩ
DC Resistance (typ) 90 mΩ
Self Resonant Frequency (min) 100 MHz
Operating Temp. Range -40 to +105 ℃
(Including-self-generated heat)
Temperature characteristic
(Inductance change)
± 25 %
Dimension L 1.6 ±0.2 mm
Dimension W 0.8 ±0.2 mm
Dimension T 0.8 ±0.2 mm
Dimension e 0.45 ±0.15 mm
Measuring Frequency 7.96 MHz
RoHS Compliance (10 subst.) Yes
REACH Compliance (247 subst.) Yes
Halogen Free Yes
Soldering Reflow
Standard Quantity Taping Embossed 3000pcs

Appearance

To Higher Specification

Smaller
Lo-Rdc Lower
Hi-Curr.

Features

Wound Chip Inductors having wide line-up, which are suitable
for any circuit designs

Main Applications

For Medical Devices classified as GHTF Classes A to B (Japan Classes Ⅰ to Ⅱ)

They are suitable for an anti-noise measure on the power supply circuit

Document

 

Simulation data

Links

 

RoHS and REACH Certificate of Compliance

Characteristic value graphs

JavaScript chart by amCharts 3.21.3LLQNB160808T1R0MImpedance0.010.11101001,00010,000Frequency[MHz]0.11101001,00010,000Impedance[ohm]
JavaScript chart by amCharts 3.21.3[Z]
JavaScript chart by amCharts 3.21.3LLQNB160808T1R0MInductance0.010.11101001,00010,000Frequency[MHz]0.000010.00010.0010.010.1110Inductance[uH]
JavaScript chart by amCharts 3.21.3[L]
JavaScript chart by amCharts 3.21.3LLQNB160808T1R0MDC Bias(L)00.050.10.150.20.250.30.350.4DC Bias[A]00.20.40.60.811.21.4Inductance[uH]
JavaScript chart by amCharts 3.21.3[DCB(L)]
The saturation current value is the DC current value having inductance decrease down to 30%. (at 20℃)
The temperature rise current value is the DC current value having temperature increase up to 40℃. (at 20℃)
Please contact our sales staff when ordering or inquiring the details about products on our website.
Information
Please be sure to read PRECAUTIONS AND DISCLAIMERS before you use TY-COMPAS.